COMPANY PROFILE        WHY US        CONTACT US        COMPANY NEWS        NEW PRODUCTS        HOME PAGE        DOWNLOADS        PRODUCTS
 
 
 

Blue black LCD black light digital display.

Micro-computer intelligent control.

Preciously presetting and controlling every operational parameter

Simultaneously displaying information about the boiler system: Overflow water temperatures of heating and domestic use: operation of fan and pump: combustion status.

Simultaneously  diagnosing mal-functions: Automatically checking operation status and eliminating  mal-functions: automatically stopping operation, alarming with buzz and displaying locations of mal-functions in case the mal-functions can not be eliminated automatically.

Presetting comfortable temperature: Presetting the best temperature for bathing with a single touch.

 

TECHNICAL PARAMETERS

HEATING SYSTEM

   

product model

DD324-B2

(DD-UK24)

UNIT

gas type

natural gas, LPG & town gas

rated input capacity

26.3 kW

rated output capacity

23.7 kW

min. input capacity for heating

11.2 kW

min. output capacity for heating

9.3 kW

min. input capacity for hot water

9.8 kW

min. output capacity for hot water

8.1 kW

efficiency

90.1 %

working pressure of heating system

0.05-0.3 MPa

max. heating water temperature

90 0C

adjustment  range of heating water temperature

40-85 0C

power supply

220-50 volt/Hz

rated electric power

125 W

degree of electrical protection

x 4D  

expansion tank volume

8 L

expansion tank preload

0.1 MPa

heating area

60-200 m2

reference gas consumption (natural gas)

1.23-2.60 m3/h

reference gas consumption (LPG)

1.00-2.10 m3/h

net weight

40 kg

dimensions

(L) 403mm, (P)342mm, (H)827mm

DOMESTIC HOT WATER SYSTEM

   

product model

DD324-B2

(DD-UK24)

UNIT

max. working pressure

0.6 MPa

min. working pressure

0.03 MPa

hot water capacity

13.6 L/min

hot water temperature adjustment  range (+/-30C)

35-60 0C

min. hot water flow for starting

2.5 L/min

limited flux

10 L/min

RATED GAS PRESSURE

   

natural gas

2000 Pa

liquid petroleum gas (LPG)

2800 PA

town gas

1000 PA

CONNECTION DIMENSIONS

   

heating system: water inlet & outlet

3/4" dia

domestic hot water system: water inlet & outlet

1/2" dia

gas system: gas inlet

3/4" dia

return

 
 